Philips HeartStart AED


Product Description

The Philips HeartStart biphasic AED (Automatic External Defibrillator) can be used on patients of any age, with the use of pedatric or adult defibrillation pads. The HeartStart has an optional training pad cartridge so staff may practice their AED skills and become familiar with the unit.  This Philips AED automatically tests all parts, including disposable pads, daily.  The HeartStart weighs 3.3 lbs with battery and pads / 2.4 lbs without.

HeartStart Benefits:

  • Lightweight:  Fully equipped at just 3.3 pounds.
  • Intuitive:  Clean design and clear voice instructions instill the confidence that's needed when administering therapy to a person in cardiac arrest.
  • Every-Ready:  Powered by a long life (4-year) disposable battery.  Automated tests help ensure readiness.
  • Versatile:  Available for use on anyone of any age, including children and infants.
  • Effective:  Patented SMART Analysis heart rhythm assessment and SMART Biphasic defibrillation therapy, clinically proven in nearly 10 years of use.  No other biphasic waveform is as well documented. 

Easy to Use:

Using the HeartStart OnSite Defibrillator is simple. Pulling the green handle powers-up the defibrillator and activates voice instructions. These instructions are paced to your actions, to help guide you through the entire process, from placing pads on the patient to delivering a defibrillation shock.

HeartStart OnSite determines if a shock is needed, based on its automated assessment of the victim's heart rhythm:

If a shock is needed, the defibrillator directs you to press the flashing orange Shock button. Then, HeartStart OnSite delivers a dose of low-energy biphasic therapy, a highly effective defibrillation waveform that is also gentle to the heart. 
If a shock is not needed, the OnSite Defibrillator instructs you to assess the patient and to perform CPR when necessary. While performing CPR, the defibrillator's voice instructions can be activated to coach you on the frequency and depth of compressions.

HeartStart OnSite also reminds you to call emergency medical services (EMS). And, should EMS need a summary of care, it can be retrieved from the defibrillator's internal memory. An EMS provider simply presses the i-button and HeartStart Onsite verbally recounts events from its last clinical use.

Replacable SMART Pads Cartridges:

The cartridge contains two adhesive pads that are peeled and placed on the patient's bare skin as indicated by the pictures on the pads. The pads are "smart" because they can sense that they have been removed from the cartridge and applied to the patient.

HeartStart OnSite can be used on patients of any age. Special Infant/Child SMART Pads reduce the defibrillator's shock energy, so that you can treat an infant or child suffering suddent cardiac arrest. The Infant/Child Pads cartridge is marked with an indication of the appropriate weight and with a teddy bear icon for ready identification.

To practice your skills, a special training pads cartridge (adult or infant/child) can be installed in the defibrillator. It suspends the defibrillator's ability to shock, while walking you through patient care scenarios.

Technical Specifications:

 

Defibrillator

Defibrillator Model

HeartStart M5066A

Defibrillator Family

HS1

How Supplied

Defibrillator, Instructions for Use, battery, adult SMART Pads cartridge (1 set), Quick Reference

Waveform

Truncated Exponential Biphasic. Waveform parameters adjusted as a function of patient impedance.

Energy

Single energy output.
Adults: nominal 150 Joules into a 50 ohm load.
Infant/Child: nominal 50 Joules into a 50 ohm load.
Automatically set based on type of SMART Pads cartridge installed.

Shock-to-Shock Cycle Time

Typically less than 20 seconds.

Protocol

Voice prompts and indicators guide user through protocol. Follows preconfigured settings. Can be modified with HeartStart Event Review software.

Voice Instructions

Detailed voice messages guide responder through use of the defibrillator.

CPR Voice Coaching

Voice instructions in adult and infant/child CPR available at user's option.

Shock Delivery

Via adhesive pads placed on patient's bare skin as illustrated on pads.

Controls

Green SMART Pads cartridge handle, Green On/Off button, Blue i-button, Orange shock button.

Indicators

Ready light; Blue i-button; Caution light.


Physical

Size
    Height
    Width
    Depth

 
2.8 inches (7 cm)
8.3 inches (21 cm)
7.4 inches (19cm)

Weight
With battery and pads cartridge
Without battery or pads cartridge


3.3 lbs (1.5 kg)
2.4 lbs (1 kg)


Environmental/Physical Requirements

Sealing

Drip proof per EN60529 class IPX1.
Solid Objects per EN60529 class IP2X.

Temperature

Operating: 32º - 122º F (0º - 50º C)
Standby: 50º - 109º F (10º - 43º C)

Humidity 

Operating: 0% to 95% relative, non-condensing
Standby: 0% to 75% relative, non-condensing

Altitude

Operating: 0 to 15,000 feet
Standby: 0 to 8,500 feet >48 hours
and 8,500 to 15,000 feet <48 hours

Shock/Drop Abuse

Withstands 1 meter drop to any edge, corner or surface.

Vibration

Meets EN1789 random and swept sine, road ambulance specification in operating and standby states.

EMI (Radiated/Immunity)

Meets EN55011 Group 1 Level B Class B and EN61000-4-3.


Patient Analysis System

Patient Analysis

Evaluates patient ECG and signal quality to determine if a shock is appropriate, and evaluates connection impedance for proper defibrillation pad contact.

Sensitivity/Specificity

Meets AAMI DF39 guidelines and AHA recommendations for adult defibrillation(Circulation 1997;95:1677-1682).

Artifact Detection

The effects of pacemaker artifact and electrical noise are minimized with artifact detection.


Battery (M5070A)

Type

9 Volt DC, 4.2 Ah, lithium manganese dioxide, disposable long-life primary cell.

Capacity

Minimum 90 shocks or 3 hours of operating time.

Install-By Date

Battery is labeled with an install-by date of at least five years from date of manufacture.

Standby Life

Four years typical when battery is installed by the install-by date.(Will power the AED in standby state within the specified standby temperature range, assuming one battery insertion test and no defibrillation uses.)


SMART Pads

Adult SMART Pads Cartridge

M5071A defibrillation pads for patients 8 years of age and older or 55 lbs. (25 kg) and over.

Infant/Child SMART Pads Cartridge

M5072A defibrillation pads for patients under 8 years of age or 55 lbs. (25 kg).

Energy Delivered

Adult: nominal 150 Joules into a 50 ohm load.
Infant/Child: nominal 50 Joules into a 50 ohm load.

How Supplied

 

Disposable cartridge, containing adhesive defibrillation pads, clicks into defibrillator for an integrated pads solution.

Active Surface Area

13.2 in2 (85 cm2 ) each

Cable Length

Adult pads: 54 inch (137.1 cm)
Infant/Child pads: 40 inch (101.6 cm)

Use-By Date

Cartridge is labeled with a use-by date of at least two years from date of manufacture.


Training Pads

Adult Training Pads Cartridge

M5073A

 

Infant/Child Training Pads Cartridge

M5074A

Function

Special pads place HeartStart OnSite into training mode and disable its energy delivery capability. Feature 8 real-world training scripts.


Automated and User Activated Self Tests

Daily Automatic Self-tests

Tests internal circuitry, waveform delivery system, pads cartridge and battery capacity.

Pads Integrity Test

Specifically tests rediness- for use of pads (gel moisture).

Battery Insertion Test

Upon battery insertion, extensive automatic self-tests and user-interactive test check device readiness.

Status Indicator

Blinking green Ready light indicates ready for use.


Data Recording and Transmission

Infrared

Wireless transmission of event data to personal computer using the IrDA protocol.

HeartStart Event Review Software

Data management software (optional) for download and review of data retrieved through defibillator's infrared data port.

Data Stored

First 15 minutes of ECG and the entire incident's events and analysis decisions.


* To see price, Warranty and fees, Talk with the specialist and hear their opinion and order this device, please call one of the following Phones;

·         07819045580

·         07706700838

·         07706700840

·         07706700841

* If you Require maintenance or having difficulties;

·         07706700839

·         07714446962

·         07819045581

 

* You are always welcomed to visit us, from 9AM to 8PM, Every day except Friday
at the following address;

Iraq, Baghdad, Palestine Street, near the Brotherhood Turkmen club

 

* Or contact us by E-Mail: medical@al-mimar.com

We are online and always ready to take your order!