DRE Echo CO2


Product Description

Effective Capnography Monitoring.

 

The DRE Echo CO2 provides cost-effective SPO2 and CO2 monitoring with accuracy and durability. The Echo CO2 ensure effective capnography monitoring for intubated and non-intubated patients for continuous long-term monitoring. It is tailored for mechanically ventilated and non-intubated patients.

FEATURES

  • 5.7 inch high resolution display for easy reading
  • Lightweight, portable design and user-friendly interface for easy operation
  • Flexible configurations to meet different clinical needs
  • Standard SpO2
  • PR measurement
  • Respironics Loflo sidestream or CAPNOSTAT 5 EtCO2 mainstream measurement
  • Real-time parameters measurement display with trend table for easy reviewing
  • Built-in rechargeable Lithium-ion battery for 10 hours continuous working
  • Powerful storage capacity
  • Bi-directional communications with central station by wired or wireless network
  • Nurse call
  • Suitable for adult, pediatric and neonatal patient

SPECIFICATIONS

  • Size: 200.8mm (L) x 241mm (H) x 189 mm (D)
  • Weight: 3 kg
  • Display: 5.7 inches
  • Color TFT resolution: 640X480
  • Power Supply: 100-240 VAC, 50/60HZ
  • Pmax=70VA FUSE T 1.6AL
  • Battery Type: Lithium-ion
  • Voltage: 14.8 V DC Capacitance: 4,400 mAh
  • Working period: Color TFT 480min
  • Rechargeable period: < 360min
  • Thermal Recorder: (Optional)
  • Record Width: 48 mm
  • Paper Speed: 25mm/s

SpO2 (Standard)

  • Measuring Range: 0 ~ 100 %
  • Alarm Range: 0 ~ 100 %
  • Resolution: 1 %

    Accuracy
    Adult (including Pediatric)
    ± 2% (70%~100% SpO2)
    Undefined 0~70% SpO2

    Neonate
    ± 3% (70%~100% SpO2)
    Undefined (0~70% SpO2)

    Pulse Rate 
    Measuring and Alarm Range: 30 ~ 300bpm
    Resolution: 1bpm
    Accuracy: ± 3bpm 
    Data update period: 2s
    ISO 9919

SpO2 (Option, by Nellcor OxiMax)

  • Measuring Range: 1 ~ 100 %
  • Alarm Range: 1 ~ 100 %
  • Resolution: 1 %

    Accuracy
    :
    Adult (including pediatric)
    ±2% (70%~100% SpO2)
    Undefined: (0~70% SpO2)

    Neonate:
    ±3% (70%~100% SpO2)
    Undefined: (0~70% SpO2)

    Pulse Rate:
    Measuring and Alarm Range: 20~300 bpm
    Resolution: 1 bpm
    Accuracy: 3 bpm

Respironics CO2

Mainstream

  • CO2 Measurement Range
    0 to 150 mm Hg,0 to 19.7%, 
    0 to 20 kPa (at 760 mm Hg)
  • Rise Time
    Less than 60 ms Adult/Infant
    Reusable or Single Patient Use
    Airway Adapter
  • CO2 Resolution
    0.1 mm Hg -- 0 to 69 mm Hg
    0.25 mm Hg -- 70 to 150 mm Hg
  • CO2 Accuracy
    0-40 mm Hg -- ±2 mmHg
    41 - 70 mm Hg -- ± 5% of reading
    71 - 100 mm Hg -- ± 8% of reading
    101 - 150 mm Hg -- ±10% of reading
    Above 80 bpm -- ±12% of reading
  • CO2 Stability
    Short Term Drift: Drift over four hours shall not exceed 0.8 mm Hg max.
    Long Term Drift: Accuracy specification will be maintained over a 120-hour period
  • Respiration Rate Accuracy
    ±1 breath
  • Calibration
    No routine user calibration required. An airway adapter zero is required when 
    changing to a different style of airway adapter
  • Water Resistance
    IPX4-Splash-proof (sensor head only)
  • Shock Impact
    EN60068-2-6 Sinusoidal Vibration
    EN60068-2-27 Shock
    EN60068-2-64 Random Vibration
    Able to withstand repeated 6 foot drops 
    onto tiled floor while operating

Sidestream

  • Sample Rate: 50 m/L per minute
  • CO2 Measurement Range:
    0 - 150 mm Hg, 0 to 20 kPa
    (at 760 mm Hg). Barometric Pressure supplied by Host
  • CO2 Resolution:
    0.1 mm Hg 0 to 69 mm Hg
    0.25 mm Hg 70 to 150 mm Hg
  • CO2 Accuracy
    0 - 40 mm Hg ±2 mm Hg
    41 - 70 mm Hg ±5% of reading
    71 - 100 mm Hg ±8% of reading
    101 - 150 mm Hg ±10% of reading
    Above 80 bpm ±12% of reading
  • CO2 Stability
    Short Term Drift: Drift over four hours shall not exceed 0.8 mm Hg max. 
    Long Term Drift: Accuracy specification will be maintained over a 120-hour period
  • Respiratory Rate Range: 2 to 150 bpm
  • Respiratory Rate Accuracy: ±1 breath
  • Sample Cell/Filter
    Proprietary single patient use sample cell and inline filter are integrated with the sample 
    line which eliminates contamination of the internal system.
  • Nasal Sampling Kits for Non-intubated Patients
    Adult, pediatric and infant nasal CO2 sampling, nasal CO2 sampling and O2 delivery 
    Adult and pediatric nasal/oral CO2sampling, nasal/oral CO2 sampling and O2 delivery
  • On-Airway Adapter KITS for Intubated Patients
    Adult/Pediatric with and without dehumidification tubing 
    Pediatric/Infant, low dead space, with and without dehumidification tubing
    Taper meets ISO 5356-1
  • Sample Kit Hours of Use
    Nasal Cannula (all styles) up to 12 hours
    On-Airway Adapter Kits without dehumidification tubing up to 12 hours
  • Sample Cell Detection
    Insertion automatically turns sampling pump on. Removal automatically turns sampling pump off.
  • Water Resistance IPX4 -Splash-proof (when sample cell is inserted in sample cell receptacle)
  • Shock ImpactIEC TR 60721-4-7 Class 7M3 
    (designed to withstand environments subject to significant vibrations or high shock levels)
    EN60068-2-27 Shock
    EN60068-2-64 Random vibration

 

* To see price, Warranty and fees, Talk with the specialist and hear their opinion and order this device, please call one of the following Phones;

  • 07819045580
  • 07706700838
  • 07706700840
  • 07706700841

* If you Require maintenance or having difficulties;

  • 07706700839
  • 07714446962
  • 07819045581


You are always welcomed to visit us, from 9AM to 8PM, Every day except Friday
at the following address;

Iraq, Baghdad, Palestine Street, near the Brotherhood Turkmen club


* Or contact us by E-Mail: medical@al-mimar.com

We are online and always ready to take your order!