Stay in touch

Address

Iraq, Baghdad, Palestine Street, near the Brotherhood Turkmen club


Phone number

Sales: 

  • 07819045580
  • 07706700838

  • 07706700840
  • 07706700841


Services: 

  • 07706700839
  • 07714446962
  • 07819045581


E-Mail:

medical@al-mimar.com


Supplies

Need supplies for your 

clinic?


  •  X Ray Film, Dry Film and Laser Film
  •  Ultrasound Coupling Gel
  • Thermal Printer Paper
  • ECG Paper
  • X Ray Contrast
  • MRI Contrast

we can provide you with these, call us now

HRX Series



This is control unit can be hung on the wall and table, can use efficiently a narrow space of operating room, can be seperated controller(supplier) and exposing part(receiver) at portable space. The distance is better within 20M.
This can after selecting value to take a picture freely, can save and take a picture with a different part of body. This display kVp, mA, mAs by digital type simultaneously, It is easy to install and use.



Features
- Realization of simple circuit using micro processor and lower error
- Easy control methods by digital display and soft touch button
- 80 Anatomical mode on memorized memory
- LV voltage auto control
- Available to broadcasting



               Specifications 

C
Spec.
Model
HRX-100T (10kW)
HRX-300T (17.5kW)
G
E
N
E
R
A
T
O
R
kVp range
40~125(2kVp steps)
40~125(1kVp steps)
mA range
50~100(8 steps)
50~300(5 steps)
Ratings
100mA@80kVp
80mA@125kVp
300mA@80kVp
200mA@125kVp
mAs range
0.415 ~ 600mAs
0.415 ∼ 1000mAs
A.P.R
80 Anatomical mode program in Memory
Self
Diagnosis
Rotor Error, Filament Error,
Tube overheat Error, Exposure Time Error
T
U
B
E
Max Volt.
125kVp
125kVp
Focal Size
0.6 - 1.2mm
1.0 - 2.0mm
0.6 - 1.2mm
1.0 - 2.0mm
Anode Heat
140KHU or 300KHU
140KHU or 300KHU

C
Spec.
Model
HRX-500T (35kW)
HRX-500T (35kW)
G
E
N
E
R
A
T
O
R
kVp range
40~125(2kVp steps)
40~150(1kVp steps)
mA range
50~500(8 steps)
50~500(8 steps)
Ratings
500mA@100kvp
300mA@125kVp
500mA@100kvp
300mA@150kVp
mAs range
0.415 ∼ 1500mAs
0.415 ∼ 1500mAs
A.P.R
80 Anatomical mode program in Memory
Self
Diagnosis
Rotor Error, Filament Error,
Tube overheat Error, Exposure Time Error
T
U
B
E
Max Volt.
125kVp
150kVp
Focal Size
0.6 - 1.2mm
1.0 - 2.0mm
0.6 - 1.2mm
1.0 - 2.0mm
Anode Heat
140KHU or 300KHU
300KHU

* A.P.R : Anatomical Programmer


* To see price, Warranty and fees, Talk with the specialist and hear their opinion and order this device, please call one of the following Phones;

  • 07819045580
  • 07706700838
  • 07706700840
  • 07706700841

* If you Require maintenance or having difficulties;

  • 07706700839
  • 07714446962
  • 07819045581


You are always welcomed to visit us, from 9AM to 8PM, Every day except Friday
at the following address;

Iraq, Baghdad, Palestine Street, near the Brotherhood Turkmen club


* Or contact us by E-Mail: medical@al-mimar.com

We are online and always ready to take your order!