MAXVISION V5 is new diagnosis HFG type X-ray system in one kind of Digital
radiography. It provides all the advantages of high frequency waveform
generators including lower patient dose, shorter exposure times and greater
accuracy and consistency.


Features
- Rapidity of diagnosis and reducing re-exposure
- immediately enable to view and Various display of Images
- Not need consumable supplies like Film, Film-processor, etc.
- Auto saving of medical image and enable to be linked with PACS/OCS
- Using Micro Process Control, Easy Operation
- High Frequency Generatior Type
- Include Self-Test Circuit that check Overload and Error
- Advanced X-ray output and high quality and lower dose
- Easy operation with APR
- Compact design ang easy Installation


Specifications
ITEM
Spec.
Model
MAXVISION V5 (5M pixel)
Detector
Number of pixel
2047 X 2477 (5 Mega Pixel)
Method
Progressive scan
Dynamic Range
79dB or more
Gray Scale
14 Bits
Line Pairs
2.8 lp/mm (Max.)
Image size
14” x 17”
Scintillator
Rare Earth
Max, Min Height
100~170cm
Protocol

DICOM 3.0 support
Enable to linked with PACS/OCS

Operating

System

PC spec.

2.4 GHz CPU, 512MB RAM, 200GB HDD
Millennium Meteo Dig/II, CD-RW
Microsoft Windows 2000 or XP

Viewer Monitor
19 inch TFT LCD Monitor
1600×1200 Resolution

Op. Software
& Viewer

MaxVue 1.6

X-ray

Generator

kVp Range
40 to 125 (1kVp STEPS)
mA Range
10 to 500(18 STEPS)
Ratings
500mA@80kvp
400mA@100kVp
200mA@125kVp
mAs range
0.1~630 mAs
A.E.C
Optional
A.P.R
Selective anatomical mode
P.S.U
Optional
Self-
Diagnosis
System
Rotor error
Filament error
Tube over heat error
Exposure time error

X-ray

Tube

Max. Voltage
125kVp
Focal Size
1.0×1.0mm / 2.0×2.0mm
Heat Unit
140KHU


* To see price, Warranty and fees, Talk with the specialist and hear their opinion and order this device, please call one of the following Phones;

  • 07819045580
  • 07706700838
  • 07706700840
  • 07706700841

* If you Require maintenance or having difficulties;